Who it is for
Most Endeavour Energy small businesses: workshops, shops, small warehouses.
Endeavour Energy · N90, N91, N92, N93, N89 · 2026–27
Most Endeavour Energy small businesses: workshops, shops, small warehouses.
Western Sydney, the Blue Mountains, Southern Highlands and the Illawarra.
The exact 2026–27 network rates sit side by side. Open a code below for the worked example, the charge window and the checks before you change anything.
| Code | What it is | Status | Access | Energy | Demand / capacity | Export | Battery fit |
|---|---|---|---|---|---|---|---|
| N90General Supply BlockLow voltage | Daily access plus two quarterly energy blocks, split at 30,000 kWh per quarter. | Available |
|
| — | — | Weak |
| N91General Supply Seasonal Time of UseLow voltage | Daily access plus high-season peak, low-season peak, solar-soak and off-peak energy rates. | Default |
|
| — | — | Conditional |
| N92General Supply DemandLow voltage | Daily access, solar-soak and other energy rates, plus seasonal peak demand charges in kW. | Optional |
|
|
| — | Strong |
| N93General Supply Transitional DemandLow voltage | Daily access, solar-soak and other energy rates, plus transitional seasonal peak demand charges in kW. | Transitional |
|
|
| — | Strong |
| N89LV Seasonal TOU TransitionalLow voltage | Daily access plus seasonal peak and off-peak energy rates, without the N19 demand component. | Transitional |
|
| — | — | Weak |
These codes share a charging method. The differences are in the rates, the time bands and who each code is for.
Most Endeavour Energy small businesses: workshops, shops, small warehouses.
Solar cuts your daytime units, which are the dearer ones. A battery matters most on N92 and N93, where flattening your peak also cuts the demand charge.
Most sites sit on N91, the default. Steady usage? Ask about N90’s block rates. Predictable 4–8pm peak? Ask about N92/N93. Your retailer decides, so ask them.
Open a code for its exact rates, the charge window, a worked example and the checks worth running before you change anything.
Businesses connected at low voltage using less than 160 MWh a year.
You pay a daily charge. The energy rate changes after the site passes a quarterly usage block.
Solar reduces the electricity the site buys. The network gives no special reward for using solar at a set time.
This tariff gives a battery no clear network target. Check retailer prices, solar exports and backup needs.
These are the network’s charges only. Your retailer adds its own prices on top.
The second block starts after 30,000 kWh in a quarter.
10,000 kWh × 16.51133 c/kWh ÷ 100$1,651.13 less in the network energy component for that quarter.This is not a retail-bill saving quote. Check how the retailer passes through network charges.
A guide, not a quote
Weak fit
This network tariff does not provide a clear demand or time-window target for a behind-the-meter battery. Any case must come from the retailer spread, solar capture or resilience value.
Businesses connected at low voltage, generally below 160 MWh a year.
You pay different energy rates at different times. Check the current time periods and seasonal rules.
Solar reduces grid use while it is generating. Its value depends on the energy rate at that time.
A battery can move energy to a more expensive period. Use actual retailer prices and allow for battery losses.
These are the network’s charges only. Your retailer adds its own prices on top.
Solar soak runs every day. Peak is business days only.
Solar soak is 10am–2pm every day. Peak is 4pm–8pm on business days.
1,000 kWh × (27.67072 − 5.68656) c/kWh ÷ 100$219.84 difference in the network energy component.The customer may not receive this spread. Use the retail contract for an investment model.
A guide, not a quote
Conditional fit
The tariff provides a time-window signal rather than a demand target. Battery value depends on a repeatable price spread, sufficient cycling volume and a control system that preserves energy for the expensive window.
Eligible businesses connected at low voltage using less than 160 MWh a year.
You pay fixed and energy charges. The bill also uses the highest kW demand in set periods.
Solar can reduce daytime grid use. If the billed peak occurs after solar output falls, solar alone will not reduce the demand charge.
A battery can reduce a billed peak. It needs enough kW and enough charge for the full event.
These are the network’s charges only. Your retailer adds its own prices on top.
Peak is business days only. All other times are off-peak.
Demand is set by the highest 30-minute reading from 4pm–8pm on a business day.
50 kW × 26.598 c/kW/day × 31 days ÷ 100$412.27 difference in the N92 network demand component for that month.A later peak can set a new billed maximum. N93 has a different rate.
A guide, not a quote
Strong fit
A recurring peak inside the tariff demand window is a direct battery target. The case weakens if the maximum is rare, unpredictable or longer than the battery can sustain.
Existing eligible low-voltage business customers transitioning toward the standard demand tariff.
You pay fixed and energy charges. The bill also uses the highest kW demand in set periods.
Solar can reduce daytime grid use. If the billed peak occurs after solar output falls, solar alone will not reduce the demand charge.
A battery can reduce a billed peak. It needs enough kW and enough charge for the full event.
These are the network’s charges only. Your retailer adds its own prices on top.
Solar soak runs every day. Peak is business days only.
Solar soak is 10:00–14:00 every day. Peak is 16:00–20:00 on business days. Demand is set from the highest 30-minute kW reading in the peak period. High season is November–March. Low season is April–October.
50 kW × 23.936 c/kW/day × 31 days ÷ 100$371.01 difference in the N93 network demand component for that month.A later peak can set a new billed maximum. This is not a retail saving. Confirm the transition path and retailer pass-through.
A guide, not a quote
Strong fit
A recurring peak inside the tariff demand window is a direct battery target. The case weakens if the maximum is rare, unpredictable or longer than the battery can sustain.
Selected businesses above 160 MWh that meet N19 criteria but lack demand-capable metering.
You pay fixed charges and an energy rate. This tariff has no demand charge.
Solar reduces the electricity the site buys. The network gives no special reward for using solar at a set time.
This tariff gives a battery no clear network target. Check retailer prices, solar exports and backup needs.
These are the network’s charges only. Your retailer adds its own prices on top.
Peak is business days only. All other times are off-peak.
Peak is 16:00–20:00 on business days. All other times are off-peak. High season is November–March. Low season is April–October. The same clock times apply in standard time and daylight saving time.
1,000 kWh × (21.45077 − 11.22506) c/kWh ÷ 100$102.26 difference in the network energy component.N89 is transitional and has no demand charge. This is not a retail saving. Confirm the replacement tariff and retailer pass-through.
A guide, not a quote
Weak fit
This network tariff does not provide a clear demand or time-window target for a behind-the-meter battery. Any case must come from the retailer spread, solar capture or resilience value.
Short answers to the things people ask before they change a tariff.
N90 is the Endeavour Energy General Supply Block tariff. It is a available low voltage tariff for Low-voltage non-residential sites using less than 160 MWh a year. Daily access plus two quarterly energy blocks, split at 30,000 kWh per quarter.
N91 is the Endeavour Energy General Supply Seasonal Time of Use tariff. It is a default low voltage tariff for Low-voltage non-residential sites, generally below 160 MWh a year. Daily access plus high-season peak, low-season peak, solar-soak and off-peak energy rates.
N92 is the Endeavour Energy General Supply Demand tariff. It is a optional low voltage tariff for Eligible low-voltage non-residential sites using less than 160 MWh a year. Daily access, solar-soak and other energy rates, plus seasonal peak demand charges in kW.
N93 is the Endeavour Energy General Supply Transitional Demand tariff. It is a transitional low voltage tariff for Existing eligible low-voltage business customers transitioning toward the standard demand tariff. Daily access, solar-soak and other energy rates, plus transitional seasonal peak demand charges in kW.
N89 is the Endeavour Energy LV Seasonal TOU Transitional tariff. It is a transitional low voltage tariff for Selected sites above 160 MWh that meet N19 criteria but lack demand-capable metering. Daily access plus seasonal peak and off-peak energy rates, without the N19 demand component.
Solar cuts your daytime units, which are the dearer ones. A battery matters most on N92 and N93, where flattening your peak also cuts the demand charge. For N90, the battery signal is weak: This network tariff does not provide a clear demand or time-window target for a behind-the-meter battery. Any case must come from the retailer spread, solar capture or resilience value.
The charges are Daily access, Time-of-use energy, Peak demand charge (N92/N93 only). The second block starts after 30,000 kWh in a quarter. Most sites sit on N91, the default. Steady usage? Ask about N90’s block rates. Predictable 4–8pm peak? Ask about N92/N93. Your retailer decides, so ask them.
Most Endeavour Energy small businesses: workshops, shops, small warehouses. The code on your retailer bill is the starting point. Your retailer must confirm any tariff assignment or change.
Effective 1 July 2026. The source includes GST-exclusive and GST-inclusive tables. These are the network charges only. Your retailer adds its own prices and may package the structure differently.
Reviewed by Mike Anderson · Last verified 7 November 2026
Effective 1 July 2026. The source includes GST-exclusive and GST-inclusive tables. These are network charges only; your retailer adds its own prices.
Free instant check